Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
NMR Biomed ; 32(12): e4178, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31608515

RESUMO

Phosphorus (31 P) MRSI provides opportunities to monitor potential biomarkers. However, current applications of 31 P MRS are generally restricted to relatively small volumes as small coils are used. Conventional surface coils require high energy adiabatic RF pulses to achieve flip angle homogeneity, leading to high specific absorption rates (SARs), and occupy space within the MRI bore. A birdcage coil behind the bore cover can potentially reduce the SAR constraints massively by use of conventional amplitude modulated pulses without sacrificing patient space. Here, we demonstrate that the integrated 31 P birdcage coil setup with a high power RF amplifier at 7 T allows for low flip angle excitations with short repetition time (TR ) for fast 3D chemical shift imaging (CSI) and 3D T1 -weighted CSI as well as high flip angle multi-refocusing pulses, enabling multi-echo CSI that can measure metabolite T2 , over a large field of view in the body. B1+ calibration showed a variation of only 30% in maximum B1 in four volunteers. High signal-to-noise ratio (SNR) MRSI was obtained in the gluteal muscle using two fast in vivo 3D spectroscopic imaging protocols, with low and high flip angles, and with multi-echo MRSI without exceeding SAR levels. In addition, full liver MRSI was achieved within SAR constraints. The integrated 31 P body coil allowed for fast spectroscopic imaging and successful implementation of the multi-echo method in the body at 7 T. Moreover, no additional enclosing hardware was needed for 31 P excitation, paving the way to include larger subjects and more space for receiver arrays. The increase in possible number of RF excitations per scan time, due to the improved B1+ homogeneity and low SAR, allows SNR to be exchanged for spatial resolution in CSI and/or T1 weighting by simply manipulating TR and/or flip angle to detect and quantify ratios from different molecular species.


Assuntos
Imageamento por Ressonância Magnética , Fósforo/química , Imagem Corporal Total , Feminino , Humanos , Fígado/metabolismo , Masculino , Músculos/metabolismo , Imagens de Fantasmas , Fosfocreatina/metabolismo
2.
PLoS One ; 12(9): e0183855, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28949967

RESUMO

PURPOSE: To establish a preoperative decision model for accurate indication of systemic therapy in early-stage breast cancer using multiparametric MRI at 7-tesla field strength. MATERIALS AND METHODS: Patients eligible for breast-conserving therapy were consecutively included. Patients underwent conventional diagnostic workup and one preoperative multiparametric 7-tesla breast MRI. The postoperative (gold standard) indication for systemic therapy was established from resected tumor and lymph-node tissue, based on 10-year risk-estimates of breast cancer mortality and relapse using Adjuvant! Online. Preoperative indication was estimated using similar guidelines, but from conventional diagnostic workup. Agreement was established between preoperative and postoperative indication, and MRI-characteristics used to improve agreement. MRI-characteristics included phospomonoester/phosphodiester (PME/PDE) ratio on 31-phosphorus spectroscopy (31P-MRS), apparent diffusion coefficients on diffusion-weighted imaging, and tumor size on dynamic contrast-enhanced (DCE)-MRI. A decision model was built to estimate the postoperative indication from preoperatively available data. RESULTS: We included 46 women (age: 43-74yrs) with 48 invasive carcinomas. Postoperatively, 20 patients (43%) had positive, and 26 patients (57%) negative indication for systemic therapy. Using conventional workup, positive preoperative indication agreed excellently with positive postoperative indication (N = 8/8; 100%). Negative preoperative indication was correct in only 26/38 (68%) patients. However, 31P-MRS score (p = 0.030) and tumor size (p = 0.002) were associated with the postoperative indication. The decision model shows that negative indication is correct in 21/22 (96%) patients when exempting tumors larger than 2.0cm on DCE-MRI or with PME>PDE ratios at 31P-MRS. CONCLUSIONS: Preoperatively, positive indication for systemic therapy is highly accurate. Negative indication is highly accurate (96%) for tumors sized ≤2,0cm on DCE-MRI and with PME≤PDE ratios on 31P-MRS.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Período Pré-Operatório
3.
NMR Biomed ; 29(6): 709-20, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27037615

RESUMO

Widespread use of ultrahigh-field (31) P MRSI in clinical studies is hindered by the limited field of view and non-uniform radiofrequency (RF) field obtained from surface transceivers. The non-uniform RF field necessitates the use of high specific absorption rate (SAR)-demanding adiabatic RF pulses, limiting the signal-to-noise ratio (SNR) per unit of time. Here, we demonstrate the feasibility of using a body-sized volume RF coil at 7 T, which enables uniform excitation and ultrafast power calibration by pick-up probes. The performance of the body coil is examined by bench tests, and phantom and in vivo measurements in a 7-T MRI scanner. The accuracy of power calibration with pick-up probes is analyzed at a clinical 3-T MR system with a close to identical (1) H body coil integrated at the MR system. Finally, we demonstrate high-quality three-dimensional (31) P MRSI of the human body at 7 T within 5 min of data acquisition that includes RF power calibration. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Imagem Molecular/instrumentação , Compostos de Fósforo/metabolismo , Isótopos de Fósforo/farmacocinética , Imagem Corporal Total/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
4.
NMR Biomed ; 27(10): 1248-55, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25146680

RESUMO

Here, we show that the sensitivity of (31)P MRSI of (31)P spins J-coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi-echo polarization transfer (DIMEPT), multiple signals from polarization transfer and direct detection can be acquired in one repetition time, with minimal mutual interference, provided that the number of refocusing pulses in the multi-echo polarization transfer part is even. The DIMEPT sequence was implemented on a 7-T body scanner and tested on a phantom and on the breasts of five healthy volunteers. The in vivo signal-to-noise ratio (SNR) enhancement for the J-coupled phosphomonoesters was 270% when compared with an Ernst angle pulse-acquire sequence. However, the phosphodiester signals, presumably mainly mobile phospholipids, had T2 values that were too short to be enhanced. Uncoupled (31)P spins, with sufficiently long T2 values, such as inorganic phosphate, were SNR enhanced by a factor of 1.9 relative to an Ernst-angle excitation pulse-acquire sequence by multi-echo direct detection.


Assuntos
Mama/química , Espectroscopia de Ressonância Magnética/métodos , Adulto , Algoritmos , Etanolaminas/análise , Feminino , Glicerilfosforilcolina/análise , Humanos , Isótopos de Fósforo , Fosforilcolina/análise , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
5.
Breast Cancer Res Treat ; 144(3): 583-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24570008

RESUMO

Phosphorus metabolite ratios are potential biomarkers in breast cancer diagnosis and treatment monitoring. Our purpose was to investigate the metabolite ratios phosphomonoester to phosphodiester, phosphoethanolamine (PE) to glycerophosphoethanolamine (GPE), and phosphocholine (PC) to glycerophosphocholine (GPC) in glandular breast tissue, and the potential effect of the menstrual cycle, using (31)P magnetic resonance spectroscopy (MRS) at 7T. Seven women with regular menstrual cycles each underwent four examinations using a 3D (31)P multi-echo magnetic resonance spectroscopic imaging sequence. Peak integrals were assessed using IDL and JMRUI software. First, T2 relaxation times were calculated using multi-echo data pooled across subjects and time points. Subsequent, metabolite ratios were calculated for each phase of the menstrual cycle using the calculated T2 values to account for when combining the free induction decay and all five echoes. The metabolite ratios were calculated both on group level and individually. T2 decay fits resulted in a T2 relaxation time for PE of 154 ms (95 % CI 144-164), for PC of 173 ms (95 % CI 148-205), for Pi of 188 ms (95 % CI 182-193), for GPE of 48 ms (95 % CI 44-53), and for GPC of 23 ms (95 % CI 21-26). The metabolite ratios analyzed on group level showed negligible variation throughout the menstrual cycle. Individual results did show an apparent intra-individual variation; however, not significant due to the measurements' uncertainty. To conclude, phospholipids in glandular tissue as measured with (31)P MRS at 7 T are not significantly affected by the menstrual cycle.


Assuntos
Mama/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Ciclo Menstrual/metabolismo , Adulto , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Metabolômica/métodos , Fósforo/metabolismo , Adulto Jovem
6.
NMR Biomed ; 26(10): 1299-307, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23553945

RESUMO

An adiabatic multi-echo spectroscopic imaging (AMESING) sequence, used for (31) P MRSI, with spherical k-space sampling and compensated phase-encoding gradients, was implemented on a whole-body 7-T MR system. One free induction decay (FID) and up to five symmetric echoes can be acquired with this sequence. In tissues with low T2 and high T2 , this can theoretically lead to a potential maximum signal-to-noise ratio (SNR) increase of almost a factor of three, compared with a conventional FID acquisition with Ernst-angle excitation. However, with T2 values being, in practice, ≤400 ms, a maximum enhancement of approximately two compared with low flip Ernst-angle excitation should be feasible. The multi-echo sequence enables the determination of localized T2 values, and was validated with (31) P three-dimensional MRSI on the calf muscle and breast of a healthy volunteer, and subsequently applied in a patient with breast cancer. The T2 values of phosphocreatine, phosphodiesters (PDE) and inorganic phosphate in calf muscle were 193 ± 5 ms, 375 ± 44 ms and 96 ± 10 ms, respectively, and the apparent T2 value of γ-ATP was 25 ± 6 ms. A T2 value of 136 ± 15 ms for inorganic phosphate was measured in glandular breast tissue of a healthy volunteer. The T2 values of phosphomonoesters (PME) and PDE in breast cancer tissue (ductulolobular carcinoma) ranged between 170 and 210 ms, and the PME to PDE ratios were calculated to be phosphoethanolamine/glycerophosphoethanolamine = 2.7, phosphocholine/glycerophosphocholine = 1.8 and PME/PDE = 2.3. Considering the relatively short T2 values of the metabolites in breast tissue at 7 T, the echo spacing can be short without compromising spectral resolution, whilst maximizing the sensitivity.


Assuntos
Mama/anatomia & histologia , Espectroscopia de Ressonância Magnética , Músculos/anatomia & histologia , Fósforo/metabolismo , Adiposidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , Fatores de Tempo , Água
7.
Schizophr Res ; 141(2-3): 153-61, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22981812

RESUMO

BACKGROUND: Membrane abnormalities in polyunsaturated fatty acids (PUFAs) have been reported in schizophrenia and have been associated with brain tissue loss in normal ageing. Therefore PUFA may be involved in the excessive brain tissue loss reported in schizophrenia. METHODS: A systematic MEDLINE database search was conducted to identify studies that compared PUFAs in erythrocyte membranes in patients and controls. Patients were categorized by medication regime in medication naive first-episode patients, and patients receiving typical or atypical antipsychotics. SAMPLE: Fourteen studies were included, comprising a total of 429 patients with schizophrenia and 444 healthy control subjects. Cohen's d effect sizes were calculated for PUFAs in erythrocyte membranes using the random-effects model. Combined Cohen's d was calculated separately for patients on different medication regime. RESULTS: Medication-naive patients and patients taking typical antipsychotics showed significantly (p<0.01) decreased concentrations of arachidonic (AA), docosahexaenoic (DHA), and docosapentaenoic (DPA) acid. In addition, patients taking typical antipsychotics showed decreased linoleic (LA), dihomo-γ-linolenic acid (DGLA), eicosapentaenoic (EPA) and docosatetraenoic (DTA) acid (p<0.01). Patients taking atypical antipsychotics showed decreased DHA (p<0.01) only. CONCLUSIONS: PUFA concentrations in erythrocyte membranes are decreased in schizophrenia. Of particular importance in patients are lower concentrations of DHA and AA, two fatty acids that are abundant in the brain and important precursors in the cell-signalling cascade.


Assuntos
Membrana Celular/metabolismo , Eritrócitos/patologia , Ácidos Graxos Insaturados/metabolismo , Esquizofrenia/patologia , Antipsicóticos/uso terapêutico , Feminino , Humanos , Masculino , Esquizofrenia/tratamento farmacológico
8.
Magn Reson Med ; 68(2): 353-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22162118

RESUMO

The sensitivity of (31)P MRS can be increased using higher magnetic fields, but also by using (1)H to (31)P polarization transfer techniques where the sensitivity is determined by the polarization of the proton spins and thus the signal-to-noise per unit time is unaffected by the slow T(1) relaxation properties of the (31)P spins. This implies that (31)P spins can be manipulated during the T(1) relaxation of the (1)H spins without affecting the signal-to-noise of the (1)H to (31)P polarization transferred spins. It is shown here that by combining (1)H to (31)P polarization transfer with a direct (31)P detection sequence in one repetition time, one can gain more signal-to-noise per unit of time as compared to a polarization transfer sequence alone. Proof of principle was demonstrated by phantom measurements and additionally the method was applied to the human calf muscle and to the human breast in vivo at 7 T.


Assuntos
Algoritmos , Mama/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético/metabolismo , Isótopos de Fósforo/análise , Processamento de Sinais Assistido por Computador , Ésteres , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...